PARAMETER_RANGE_CONTINUOUS
Parameters and functions
*PARAMETER_RANGE_CONTINUOUS
rid
$r_{min}$, $r_{max}$, $\Delta r$
rid
$r_{min}$, $r_{max}$, $\Delta r$
Parameter definition
Variable
Description
rid
Range ID
$r_{min}$
Minimum allowed parameter value
$r_{max}$
Maximum allowed parameter value
$\Delta r$
Parameter increment
Description
This command specifies a continuous range of allowed values for a parameter defined under PARAMETER. It is exclusively used by the GUI to simplify the visualization and adjustment of specific parameters.
Example
Parameter range
Specify the allowed range of %alpha. %alpha can be adjusted in the GUI, but only within the given range (between 10 and 45 degrees).
*PARAMETER
%alpha = 15.0, "impact angle", 1234
*PARAMETER_RANGE_CONTINUOUS
1234
10.0, 45.0